Tlines Intelligence
中文
medRxiv Daily PicksFlash0 views

Stanford trial: high-autonomy LLM vancomycin dosing agent cuts error versus low-autonomy setup

Sourcesmedrxiv.org

[medRxiv] A preprint study conducted at Stanford Hospital reported that researchers silently deployed PharmaAgent, an LLM-based vancomycin dosing agentic system, for two months and compared high- and low-autonomy configurations, each with and without institutional guidelines. Across 403 dosing events in 316 patients, mean absolute percentage error against the treating pharmacist's order was 21.8% with high autonomy versus 37.8% with low autonomy, and recommendations were within 25% of the order in 73.4% versus 50.9% of events (P < 0.001), according to the study; a second pharmacist was within 25% of the treating pharmacist's order in 90.2% of events. Pharmacist review of 196 out-of-tolerance recommendations found a safety concern in 65.8%, more often with low autonomy (odds ratio 2.37). The authors said a higher-autonomy agent that self-debugged its steps proved more robust than stricter engineering, but that neither configuration is ready to dose patients without pharmacist oversight.

More frommedRxiv Daily Picks → · All news →